20% OFF shipping at saep.cl on orders over $79 + up to 10% OFF products
saep.cl
home > SHA852A Siglent Signal Analyzer New > SHA852A Siglent Signal Analyzer New
download picture
SHA852A Siglent Signal Analyzer NewKey Features at a Glance Frequency: 9 kHz to 7. 5 GHz Functions: Spectrum analyzer, VNA, CAA, signal generator, power meter, EMI, modulation DANL: 160 dBm Hz typical (preamp on) SSB Phase Noise: 95 dBc Hz typ. at 1 GHz, 10 kHz offset RBW: 1 Hz to 10 MHz VNA CAA: S11, S21, VSWR, return loss, cable loss, DTF Display: 10. 1 inch multi touch, battery operation Remote: SCPI LabVIEW IVI; LAN, USB, web browser About the Siglent SHA852A In summary, the
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Key Features at a Glance

  • Frequency: 9 kHz to 7.5 GHz
  • Functions: Spectrum analyzer, VNA, CAA, signal generator, power meter, EMI, modulation
  • DANL: -160 dBm/Hz typical (preamp on)
  • SSB Phase Noise: -95 dBc/Hz typ. at 1 GHz, 10 kHz offset
  • RBW: 1 Hz to 10 MHz
  • VNA / CAA: S11, S21, VSWR, return loss, cable loss, DTF
  • Display: 10.1 inch multi-touch, battery operation
  • Remote: SCPI / LabVIEW / IVI; LAN, USB, web browser

About the Siglent SHA852A

In summary, the Siglent SHA852A is a handheld multi-function RF analyzer covering 9 kHz to 7.5 GHz, combining spectrum analyzer, vector network analyzer, cable-and-antenna analyzer, signal generator, power meter, EMI pre-compliance, and modulation analysis functions in a battery-powered field-portable enclosure. Per the datasheet, the SHA852A provides -160 dBm/Hz typical displayed average noise level with the preamplifier on, -95 dBc/Hz typical SSB phase noise at 1 GHz / 10 kHz offset, and a 10.1 inch capacitive multi-touch screen, on a single instrument that field service technicians can carry to a cell tower, antenna site, or remote installation.

What is the Siglent SHA852A used for?

The SHA852A is used for field cellular site work, antenna and feedline characterization, transmitter verification, interference hunting, and EMI pre-compliance — applications that historically required a separate spectrum analyzer, VNA, cable-and-antenna analyzer, and signal generator. Per the datasheet, the SHA852A supports cable loss, return loss, VSWR, distance-to-fault (DTF), S-parameters (S11, S21), insertion loss, full two-port transmission measurement, channel power, ACPR, OBW, and CISPR 16-1-1 compliant EMI quasi-peak detection — on the same handheld instrument.

How does the SHA852A compare to a benchtop spectrum analyzer?

A benchtop spectrum analyzer is optimized for a lab bench: AC mains, large display, deep specification depth, and (typically) better phase noise and dynamic range. A handheld instrument like the SHA852A is optimized for the field: battery operation, weather-tolerant enclosure, GPS receiver for site tagging, and integrated cable-and-antenna analyzer functions that lab instruments rarely include in a single chassis. Per the datasheet, the SHA852A delivers benchtop-class spectrum analyzer specifications — -160 dBm/Hz typical DANL, -95 dBc/Hz typical SSB phase noise, and 1 Hz to 10 MHz RBW — combined with field-grade VNA and CAA functions, on a battery-powered handheld designed for tower-crew and field-service work.

Where does the SHA852A fit in a field RF kit?

  • Cellular site verification, tower-mounted antenna tests, and feedline characterization up to 7.5 GHz.
  • Distance-to-fault (DTF) measurement on coaxial feedlines to locate connector damage, water ingress, and feedline kinks.
  • Cable loss, return loss, VSWR, S11, and S21 measurements via the integrated vector network analyzer mode.
  • Spectrum monitoring for interference hunting and licensed-band verification, with GPS time and position stamping of captured signals.
  • EMI pre-compliance investigation at customer sites with CISPR 16-1-1 quasi-peak detection.
  • Field-service measurements that previously required carrying three or four separate instruments.

Accessories Supplied

Per the manufacturer datasheet, the standard ship kit includes: a Quick Start guide, a battery pack, a region-appropriate AC adapter, and a carrying strap. A carrying case, calibration kit (for VNA / CAA operation), additional batteries, and RF cables / adapters are available as optional accessories from the manufacturer.

Core Specifications

Frequency, Reference, and Bandwidth

Frequency range 9 kHz to 7.5 GHz
Frequency resolution 1 Hz
Span range 0 Hz (Zero Span), 100 Hz to maximum frequency
Internal reference (10 MHz) Aging < 1 ppm/yr; temperature stability < 1 ppm
GPS-disciplined reference Yes, with optional GPS antenna
RBW (-3 dB) 1 Hz to 10 MHz, 1-3-10 sequence
VBW (-3 dB) 1 Hz to 10 MHz, 1-3-10 sequence
EMI filter (-6 dB) 200 Hz, 9 kHz, 120 kHz, 1 MHz (CISPR 16)

Amplitude, Level, Phase Noise (Spectrum Analyzer Mode)

Measurement range (preamp off) DANL to +30 dBm
Reference level -100 dBm to +30 dBm, 1 dB steps
Preamplifier Approximately 20 dB nominal
Input attenuation 0 to 50 dB, 1 dB steps
Maximum continuous power +30 dBm (1 W)
Maximum input DC voltage ± 50 VDC
Traces / detectors 4 / Pos-peak, Neg-peak, Sample, Normal, Average
DANL, preamp on (typ.) -160 dBm/Hz at 100 MHz
SSB phase noise at 1 GHz, 10 kHz offset < -90 dBc/Hz; -95 dBc/Hz typical
Absolute amplitude accuracy at 50 MHz ± 0.5 dB
Third-order intercept (TOI) +10 dBm typical

Vector Network Analyzer / Cable-and-Antenna Mode

VNA / CAA frequency range 9 kHz to 7.5 GHz
Test ports Two (N-type female)
Measurement parameters S11 magnitude / phase, S21 magnitude / phase, VSWR, return loss, cable loss, distance-to-fault (DTF), Smith chart, group delay
Number of trace points Up to 10001
Sweep types Linear frequency, segment
Calibration types OSL (Open / Short / Load), full two-port, normalization
Output power -45 dBm to 0 dBm, 1 dB steps
Dynamic range > 80 dB typical
Cable list (for DTF) Pre-populated standard cable types editable by user

Signal Generator, Power Meter, EMI, Modulation

Signal generator (option) Internal source for stimulating DUTs; output level -45 dBm to 0 dBm
Power meter (option) Compatible with USB power sensors for accurate absolute power measurement
EMI Measurement (option) Peak, Average, Quasi-Peak detectors (CISPR 16-1-1); pre-loaded EN 55022, FCC Part 15 limit standards
Modulation Analysis (option) AM, FM, ASK, FSK demodulation and quality measurement
Channel-power measurements Channel Power, ACPR, OBW, T-Power, Harmonic, TOI

Battery, Display, and General

Display TFT LCD, 1280 × 800, 10.1 inch multi-touch capacitive
Battery operation Lithium-ion battery pack, approximately 4 hours typical operation
Internal storage ≥ 8 GB
Dimensions (W×H×D, approx.) 330 × 220 × 90 mm
Weight (with battery, approx.) approximately 3.4 kg (7.5 lb)
AC source (charger) 100-240 V, 50/60 Hz; auto-sensing
Operating temperature / humidity -10 to +50 °C; ≤ 90% RH at 30 °C, non-condensing
Enclosure Field-tolerant chassis; not a fully sealed IP-rated unit — protect from sustained weather exposure
Safety / EMC / RoHS EN 61010-1; EN 61326-1; 2011/65/EU
Remote interfaces LAN, USB Device, USB Host; SCPI / LabVIEW / IVI; HTML5 web browser

Note on Calibration Kit Requirement

Cable, antenna, and VNA measurements on the SHA852A require a calibration kit appropriate to the test-port connector type. The calibration kit is NOT part of the standard ship kit and must be ordered separately. For N-type test ports, an N-type Open / Short / Load (OSL) calibration kit is typically required; SMA adapters and N-to-SMA precision adapters are also commonly needed. Confirm calibration kit requirements at the time of order.

Note on Optional Features

Several measurement modes — including signal generator, power meter, EMI Measurement, and Modulation Analysis — are software options that may be field-upgraded or factory-installed. Confirm at the time of order which options are required for the target application.

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

SHA852A Siglent Signal Analyzer New

Item no : 39440444359
sold recently : Login >>
US$ 4399.00
Pay in 4 interest-free payments of $1099.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 20 - Jun 25

Enjoy 20% off shipping

US$ 4399.00

1-11

US$ 3959.10

12-35

US$ 3079.30

36-59

US$ 2639.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Gäle
Gäle

US$ 50.95

Min. order: 1 piece

4.9 (297 reviews)

Sold : Login>>

Related Searches